Language
ABOUT US

BUSINESS

Electrobath manufacturing device


The electrobath manufacturing
device makes the electrobath used
with the grain degree weighing
device (electric resistance method
counter).

As for the electrobath made with
the electrobath manufacturing
device, a measurement that not
only removes the foreign body but
also is steady with the grain degree
weighing device can be done.

A changeable thing can also do the
density of electrobath.

The aqua pura can be used at any
time.

The system configuration can be
set even in narrow space next to
the grain degree weighing device
because it divides into three
systems (the pure water machine
system, the main body of the
electrobath manufacturing device,
and the sampling tower) and it
enters. Electrobath for the grain
degree assumption device can be
gathered always easily.




The control of the density of electrobath that cannot be doneby usual electrobath can be easily done.
The temperature of electrobath can be easily controlled by theoption.
Because a difficult measurement is steady up to now, it ispossible to measure it.

Specification / Type
Main body IH-260
Sampling tower IH-HS10E1
Pure water machine PRO-0100-002
Voltage 100(V) 50Hz or 60Hz
Method of note Automatic fixed quantity tank of type (programmed control method withsequencer)
  Three function electrobath pure water automatic layer
  Electrobathpure water lowest amount 20 liters.. (arbitrary, manual density)
  Pure water ability 140/h(25 degrees in water temperature)
Pump
 water current pump No load  24/27(Litter/Minutes)
  1(A) 15/18(Litter/Minutes)
  4(A) 18/21(Litter/Minutes)
 Mixture Oceki pump No load  12/14(Litter/Minutes)
Timer Method arbitrariness set of two timers
Capacity of tank 40 (liter) in capacity 60 (liter) specifications in capacity of tank
Electrolyte 400(g) one use for 1(%) Nacl usual electrolyte electrobath.
Weight main body weight    About 145 (kg)
Main body sizes 985×460×750
Pure water machine 500×400×1295
Weight main body weight About 130 (kg)
Pure water machineIndicator It uses it by turning on in the pure water machine indicator automaticoperation driving.
  The pump cannot wash RO automatically when turning it off.
  そAdditionally, the water quality can be monitored.
  The use time of the filter can be managed.
Installed Inventory Click here for details

Contact

Please feel free to contact us by e-mail listed below.

Address:info@woca-jp.com (@ is listed as double bytes code to avoid spam mail.Please  change it to 1 byte  code when you send an e-mail to us)


Others

 1) The aqua pura of a constant amount automatically enters the tank.
      A set amount is about 40(liter).

 The example) When you set the density of electrobath to 0 and 85(%).
     When this condition dissolves Nacl of 340(g) to the tank setting amount,
              the density of electrobath is made.
       Present setting 340(g) ÷40000(cc) ×100≒ 0
                    and Nacl(g) ÷85 in density (%) of electrobath (cc) ×100 tank capacity ≒(%)
         
       Please put 340(g) in the electrolyte.
       Nacl has the grade, and use the grade of the class or more of one, please.
       (Please use the high grade as much as possible. )

      ※The density of electrobath changes if it makes a mistake in the
                     electrolyte, except for being filled with water of the tank and it puts it.
        Please exhaust once and make it again when making a mistake.

 2) Please confirm it to the aqua pura with the conduction meter of the pure
      water machine following 1(μS/cm).
   There is a thing that the measurement data becomes unstable more than this.

 3) Five in all is used, and three filters are used for the pure water making.
   From tap water entrance to activated carbon, RO module,
      and the order of ion exchange resin it.
   The use time is the longest and one year from half a year.
   Please note that the use time changes respectively.

   When the activated carbons are attentively exchanged,
      the longevity of the RO module and the ion exchange resin becomes long.
   The activated carbon plays the role of Prifiltar.
   When the water quality is bad, the filter is put in the former steps.
   The exchange time changes into the RO module depending on the water quality.
   It usually becomes an exchange in one year from about six months
      though the ion exchange resin depends on the amount of use.
   2BS and 4BS main body filter are also similar.

    ※  The amount of the exhalation of electrobath decreases
                 when the filter is blocked.
      Moreover, the background goes up suddenly occasionally.
                 (Depend on the microorganism breeding. )
      Please prepare the reserve in the filter beforehand.

 4) Explanation of each switch of sampling tower

   The power switch   Power supply is turned on and off.
              There is a leak main switch on the other side of the main body.
              The power supply doesn't enter if the switch is not turned on.
              Moreover, the power lamp on the main body table side lights
                                       when the main switch is turned on.

   The pump switch  Pump is turned on and off.
               It uses it by turning on usually.
                                        It is an automatic driving. (Operate for five minutes. )


   The alarm switch    The aqua pura is demanded by the alarm switch alarm.
              The alarm sound is erased with ON/OFF.
               It uses it by turning on usually.

   A timer           A sampling duration is set.
   B timer           B sampling duration is set.
               The amount in which electrobath is taken out of the sample tray is set.
               It somewhat changes into the guess of the tank.

   The temperature   The temperature of water temperature meter electrobath is displayed.
               The water temperature in summer of winter is different,
                                        and use the usetemperature as much as possible,
                                        please 20(℃)30 the(℃) best on a good condition.
               Moreover, mixing air increases because there is
                                        a lot of ..low.. Zon oxygens the water temperature.